CVE-2024-39512 Vulnerability Details

  /     /     /  

CVE-2024-39512 Metadata Quick Info

CVE Published: 10/07/2024 | CVE Updated: 02/08/2024 | CVE Year: 2024
Source: juniper | Vendor: Juniper Networks | Product: Junos OS Evolved
Status : PUBLISHED

CVE-2024-39512 Description

An Improper Physical Access Control vulnerability in the console port control of Juniper Networks Junos OS Evolved allows an attacker with physical access to the device to get access to a user account. When the console cable is disconnected, the logged in user is not logged out. This allows a malicious attacker with physical access to the console to resume a previous session and possibly gain administrative privileges. This issue affects Junos OS Evolved: * from 23.2R2-EVO before 23.2R2-S1-EVO,  * from 23.4R1-EVO before 23.4R2-EVO.

Metrics

CVSS Version: 3.1 | Base Score: 6.6 MEDIUM
Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

l➤ Exploitability Metrics:
    Attack Vector (AV)* PHYSICAL
    Attack Complexity (AC)* LOW
    Privileges Required (PR)* NONE
    User Interaction (UI)* REQUIRED
    Scope (S)* UNCHANGED

l➤ Impact Metrics:
    Confidentiality Impact (C)* HIGH
    Integrity Impact (I)* HIGH
    Availability Impact (A)* HIGH

Weakness Enumeration (CWE)

CWE-ID: CWE-1263
CWE Name: CWE-1263 Improper Physical Access Control
Source: Juniper Networks

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description:


Source: NVD (National Vulnerability Database).