CVE-2024-2856 Vulnerability Details

  /     /     /  

CVE-2024-2856 Metadata Quick Info

CVE Published: 24/03/2024 | CVE Updated: 21/08/2024 | CVE Year: 2024
Source: VulDB | Vendor: Tenda | Product: AC10
Status : PUBLISHED

CVE-2024-2856 Description

A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Metrics

CVSS Version: 3.1 | Base Score: 8.8 HIGH
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

l➤ Exploitability Metrics:
    Attack Vector (AV)*
    Attack Complexity (AC)*
    Privileges Required (PR)*
    User Interaction (UI)*
    Scope (S)*

l➤ Impact Metrics:
    Confidentiality Impact (C)*
    Integrity Impact (I)*
    Availability Impact (A)*

Weakness Enumeration (CWE)

CWE-ID: CWE-121
CWE Name: CWE-121 Stack-based Buffer Overflow
Source: Tenda

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description: