CVE-2023-52891 Vulnerability Details

  /     /     /  

CVE-2023-52891 Metadata Quick Info

CVE Published: 09/07/2024 | CVE Updated: 02/08/2024 | CVE Year: 2023
Source: siemens | Vendor: Siemens | Product: SIMATIC Energy Manager Basic
Status : PUBLISHED

CVE-2023-52891 Description

A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A successful attack may lead to high load situation and memory exhaustion, and may block the server.

Metrics

CVSS Version: 3.1 | Base Score: 5.3 MEDIUM
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

l➤ Exploitability Metrics:
    Attack Vector (AV)*
    Attack Complexity (AC)*
    Privileges Required (PR)*
    User Interaction (UI)*
    Scope (S)*

l➤ Impact Metrics:
    Confidentiality Impact (C)*
    Integrity Impact (I)*
    Availability Impact (A)*

Weakness Enumeration (CWE)

CWE-ID: CWE-1325
CWE Name: CWE-1325: Improperly Controlled Sequential Memory Allocation
Source: Siemens

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description:


Source: NVD (National Vulnerability Database).