CVE-2023-23771 Vulnerability Details

  /     /     /  

CVE-2023-23771 Metadata Quick Info

CVE Published: 29/08/2023 | CVE Updated: 02/10/2024 | CVE Year: 2023
Source: NCSC-NL | Vendor: Motorola | Product: MBTS Base Radio
Status : PUBLISHED

CVE-2023-23771 Description

Motorola MBTS Base Radio accepts hard-coded backdoor password. The Motorola MBTS Base Radio Man Machine Interface (MMI), allowing for service technicians to diagnose and configure the device, accepts a hard-coded backdoor password that cannot be changed or disabled.

Metrics

CVSS Version: 3.1 | Base Score: 8.4 HIGH
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:H/RL:U/RC:C/CR:H/IR:H/AR:M/MAV:L/MAC:L/MPR:N/MUI:N/MS:U/MC:H/MI:H/MA:H

l➤ Exploitability Metrics:
    Attack Vector (AV)* LOCAL
    Attack Complexity (AC)* LOW
    Privileges Required (PR)* NONE
    User Interaction (UI)* NONE
    Scope (S)* UNCHANGED

l➤ Impact Metrics:
    Confidentiality Impact (C)* HIGH
    Integrity Impact (I)* HIGH
    Availability Impact (A)* HIGH

Weakness Enumeration (CWE)

CWE-ID: CWE-259
CWE Name: Use of Hard-coded Password
Source: Motorola

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description:


Source: NVD (National Vulnerability Database).