CVE-2022-40202 Vulnerability Details

  /     /     /  

CVE-2022-40202 Metadata Quick Info

CVE Published: 31/10/2022 | CVE Updated: 03/08/2024 | CVE Year: 2022
Source: icscert | Vendor: Delta Electronics | Product: InfraSuite Device Master
Status : PUBLISHED

CVE-2022-40202 Description

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

Metrics

CVSS Version: 3.1 | Base Score: 9.8 CRITICAL
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

l➤ Exploitability Metrics:
    Attack Vector (AV)* NETWORK
    Attack Complexity (AC)* LOW
    Privileges Required (PR)* NONE
    User Interaction (UI)* NONE
    Scope (S)* UNCHANGED

l➤ Impact Metrics:
    Confidentiality Impact (C)* HIGH
    Integrity Impact (I)* HIGH
    Availability Impact (A)* HIGH

Weakness Enumeration (CWE)

CWE-ID: CWE-306
CWE Name: CWE-306 Missing Authentication for Critical Function
Source: Delta Electronics

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description:


Source: NVD (National Vulnerability Database).