CVE-2021-3774 Vulnerability Details

  /     /     /  

CVE-2021-3774 Metadata Quick Info

CVE Published: 05/11/2021 | CVE Updated: 03/08/2024 | CVE Year: 2021
Source: INCIBE | Vendor: Meross | Product: Meross Smart Wi-Fi 2 Way Wall Switch
Status : PUBLISHED

CVE-2021-3774 Description

Meross Smart Wi-Fi 2 Way Wall Switch (MSS550X), on its 3.1.3 version and before, creates an open Wi-Fi Access Point without the required security measures in its initial setup. This could allow a remote attacker to obtain the Wi-Fi SSID as well as the password configured by the user from Meross app via Http/JSON plain request.

Metrics

CVSS Version: 3.1 | Base Score: 7.4 HIGH
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:N/A:N

l➤ Exploitability Metrics:
    Attack Vector (AV)* NETWORK
    Attack Complexity (AC)* LOW
    Privileges Required (PR)* NONE
    User Interaction (UI)* REQUIRED
    Scope (S)* CHANGED

l➤ Impact Metrics:
    Confidentiality Impact (C)* HIGH
    Integrity Impact (I)* NONE
    Availability Impact (A)* NONE

Weakness Enumeration (CWE)

CWE-ID: CWE-319
CWE Name: CWE-319 Cleartext Transmission of Sensitive Information
Source: Meross

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID:
CAPEC Description:


Source: NVD (National Vulnerability Database).