CVE-2021-34577 Vulnerability Details

  /     /     /  

CVE-2021-34577 Metadata Quick Info

CVE Published: 09/11/2022 | CVE Updated: 04/08/2024 | CVE Year: 2021
Source: CERTVDE | Vendor: Kaden | Product: PICOFLUX AiR
Status : PUBLISHED

CVE-2021-34577 Description

In the Kaden PICOFLUX AiR water meter an adversary can read the values through wireless M-Bus mode 5 with a hardcoded shared key while being adjacent to the device.

Metrics

CVSS Version: 3.1 | Base Score: 6.5 MEDIUM
Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

l➤ Exploitability Metrics:
    Attack Vector (AV)* ADJACENT_NETWORK
    Attack Complexity (AC)* LOW
    Privileges Required (PR)* NONE
    User Interaction (UI)* NONE
    Scope (S)* UNCHANGED

l➤ Impact Metrics:
    Confidentiality Impact (C)* HIGH
    Integrity Impact (I)* NONE
    Availability Impact (A)* NONE

Weakness Enumeration (CWE)

CWE-ID: CWE-798
CWE Name: CWE-798 Use of Hard-coded Credentials
Source: Kaden

Common Attack Pattern Enumeration and Classification (CAPEC)

CAPEC-ID: CAPEC-21
CAPEC Description: CAPEC-21 Exploitation of Trusted Credentials


Source: NVD (National Vulnerability Database).