Malware Built to Hack Building Automation Systems

  /     /     /  
Publicated : 23/11/2024   Category : security


Malware Built to Hack Building Automation Systems


Researchers dig into vulnerabilities in popular building automation systems, devices.



S4x19 -- Miami -- Researchers who discovered multiple vulnerabilities in building automation system (BAS) equipment have also constructed proof-of-concept malware to exploit some of those security weaknesses.
Security researcher Elisa Costante and her team at ForeScout last summer created the test malware – a modular design that includes a worm that spreads itself among BAS devices – using intelligence they gathered over the past three years while testing popular BAS systems, such as protocol gateways and PLCs for HVACS and access control, for vulnerabilities. During that period, they uncovered 10 security flaws, half of which were cross-site scripting (XSS) bugs in their associated Web application interfaces, as well as privilege escalation and buffer overflow vulnerabilities.
Costante shared the teams research here at S4x19 this week.
While the affected BAS vendors - which ForeScout declined to reveal - have since patched the vulnerabilities, more than 11,000 of the affected devices today remain exposed on the public Internet to the buffer overflow flaw, mostly in schools and hospitals, due to poor patching processes or none at all, Costante says. Some had already fixed the flaws quietly in new versions of the devices.
You still have a lot of [BAS] devices running on old firmware, Costante said in an interview with Dark Reading. BAS devices and equipment dont get updated or replaced regularly: Some 60% of BAS products in place today are around 20 years old, she said.
Building systems are the oft-forgotten and increasingly network-connected piece of the security puzzle. They fall into a category of their own and rarely are updated or vetted for security. BAS control systems manage and run physical operations of a building, such as HVAC, elevators, physical access control, and video surveillance.
A lot of times, building automation systems sit on the enterprise, but IT has no access to them, said Dale Peterson, CEO of Digital Bond and the head of the S4 ICS SCADA conference. Theyre not behind the firewall or [part of] ICS ... and theyre not run by IT. Its a little group doing their own thing.
BAS SCADA systems often are older and not typically considered part of the overall IT infrastructure, noted Eddie Habibi, CEO of ICS security vendor PAS. Protecting them could be a lot easier than an OT network, he said, but most BAS managers dont even consider the cybersecurity of those systems. Its OK to do a 10-minute shutdown [for patching a BAS], he said. Youre not running a refinery.
Building Hacks
BAS hacking already is starting to become a thing: In a report published today on its BA system security findings and malware, ForeScout cited a 2016 ransomware attack on a hotel in Austria that targeted room locks and a distributed-denial-of-service (DDoS) attack that hit heating systems in two apartment buildings in Finland. And among some of the juicier BAS targets are data centers, for example, where temperature fluctuations via a hacked HVAC could wreak havoc and ruin computers, ForeScout said.
Costante said her teams goal was to create complex malware that couldnt be traced by forensics. They decided to first target in the malware an Internet-facing IP camera, which then spread to a workstation that ultimately got them to their target: the PLC that controls the building automation process. From the Windows workstation, we use the core part of the malware, the exploitation of the buffer overflow [vulnerability], she said.
The malware could be used to open a restricted phyisical access area to an attacker, such as a restricted area in an airport, she said.
ForeScout spent a total of $12,000 on the malware and equipment for the project, which Costante said demonstrates that BAS hacking doesnt require heavily resourced nation-state backing, for example. And part of the goal of the research was to test the vulnerability of BAS and possible attack scenarios.
There was a lack of awareness on what you can do with buildings and how easy and exposed they are, Costante said.
Meanwhile, some building management operations are starting to find cybersecurity religion. David Weinstein, vice president of threat research at Claroty, said his company is seeing major real estate firms inquiring about securing their properties building automation systems. More CISOs are taking responsibility for OT and IoT, he said, and that also brings BAS into the security equation.
Related Content:
Hijacking a PLC Using its Own Network Features
Triton/Trisis Attack Was More Widespread Than Publicly Known
7 Privacy Mistakes That Keep Security Pros on Their Toes
2019 Attacker Playbook

Last News

▸ Scan suggests Heartbleed patches may not have been successful. ◂
Discovered: 23/12/2024
Category: security

▸ IoT Devices on Average Have 25 Vulnerabilities ◂
Discovered: 23/12/2024
Category: security

▸ DHS-funded SWAMP scans code for bugs. ◂
Discovered: 23/12/2024
Category: security


Cyber Security Categories
Google Dorks Database
Exploits Vulnerability
Exploit Shellcodes

CVE List
Tools/Apps
News/Aarticles

Phishing Database
Deepfake Detection
Trends/Statistics & Live Infos



Tags:
Malware Built to Hack Building Automation Systems