Industrial Systems Suffer From Poor Patching, Bad Password Practices – Study

  /     /     /  
Publicated : 23/11/2024   Category : security


Industrial Systems Suffer From Poor Patching, Bad Password Practices – Study


Industrial control systems are riddled with outdated software that is in need of patching, while passwords are stored in plain text and endpoints are left open to attack, according to a report from CyberX.



Increasingly, industrial control systems (ICS) are coming under attack from nation-states and other bad actors, due to poor patching practices and outdated software being exposed to the public-facing Internet. Now, a new report find out just how bad this situation has become.
Much of what cybersecurity firm CyberX finds in its survey,
Global ICS & IIoT Risk Report
, runs counter to the usual thinking about security and ICS. To draw its conclusions, researchers looked at data from 850 production industrial networks between September 2017 and September 2018.
What they found is that many operators think that Operational Technology (OT) networks dont need to be monitored or patched since they are isolated from the Internet thanks to air-gaps, or that these networks are based on proprietary devices and protocols and are secure.
(Source:
Pixabay
)
Now, however, OT networks are becoming increasingly connected to corporate IT networks, which can provide an attack surface. Indeed, CyberX found that 40% of industrial sites have at least one connection to the public-facing Internet.
The lack of patching and attention contributes to the reports finding that 53% of the sites have obsolete Microsoft Windows systems, such as Windows XP. Due to ICS-specific factors such as narrow maintenance windows, legacy applications and older hardware, it may not always be possible to patch or upgrade systems to more modern versions.
But this is one area that has improved when compared to last years ICS report. In 2017, there were legacy Windows systems in 76% of sites and that has now dropped to 53% of sites.
Additionally, 69% of the industrial firm systems have plain-text passwords that traverse their ICS networks. These can easily be sniffed by attackers that perform cyber-reconnaissance. These sorts of passwords are typically associated with legacy devices that dont support modern, secure protocols such as SNMP v3 or SFTP.
Alarmingly, 57% of ICS sites were found not to be running anti-virus protections that update signatures automatically. This reliance on outdated and ineffectual signature lists will increase the risk of malware infections.
But this is also an indication of past beliefs of ICS equipment vendors.
These supply firms may not have permitted installation of any AV at all on their devices since they believed that AV scanning would cause latency issues that would negatively affect time-critical processes. That has changed, and most vendors now have certified both AV, as well as application whitelisting solutions. But misuse of AV due to legacy issues continues.
The report also found that 16% of sites were found to have at least one wireless access point, which can include routers, VPN gateways or switches that can serve as a point of entry for attackers.
Finally, 84% of industrial sites were found to have at least one remotely accessible device. This is significant since remote management and access protocols such as RDP, VNC and SSH make it easier for administrators to remotely configure devices. But they also make it easier to attackers with stolen credentials to learn exactly how equipment is configured and then manipulate it.
These kinds of devices are where an attacker will begin their breach attempts.
CyberX makes some general recommendations for mitigating the risk in the report. First, the firm advise reducing the number of digital pathways to a minimum, which helps cut down on possible attack paths.
Second, identify ICS network and endpoint vulnerabilities. Vulnerabilities such as weak passwords and the closing of unused open ports would be taken care of in this effort.
Lastly, implementing of continuous ICS monitoring. The report believes that that ICS-specific behavioral anomaly detection is essential for early detection of targeted and zero-day attacks that signature-based solutions may miss.
Related posts:
GreyEnergy Group Tied to Power Plant Attacks in Ukraine & Poland
Fujis Electric V-Server Susceptible to Numerous Vulnerabilities
Kaspersky: Spear-Phishing Attacks Target 400 Industrial Companies
ICS Network Managers: Time for a Wake-Up Call
— Larry Loeb has written for many of the last centurys major dead tree computer magazines, having been, among other things, a consulting editor for BYTE magazine and senior editor for the launch of WebWeek.

Last News

▸ Scan suggests Heartbleed patches may not have been successful. ◂
Discovered: 23/12/2024
Category: security

▸ IoT Devices on Average Have 25 Vulnerabilities ◂
Discovered: 23/12/2024
Category: security

▸ DHS-funded SWAMP scans code for bugs. ◂
Discovered: 23/12/2024
Category: security


Cyber Security Categories
Google Dorks Database
Exploits Vulnerability
Exploit Shellcodes

CVE List
Tools/Apps
News/Aarticles

Phishing Database
Deepfake Detection
Trends/Statistics & Live Infos



Tags:
Industrial Systems Suffer From Poor Patching, Bad Password Practices – Study